The devices are designed to measure the strength of direct current in electric circuits.
Shields of the magneto-electric system with an arrow pointer with the mounting of the moving part on the cores.
The working position is vertical, horizontal (depending on the order).
Name, type, measurement range, accuracy class are listed below:
Name
|
Accuracy class
|
Measuring range
|
Microammeter
|
2,5; 4
|
from 500 µA (250–0–250) µA
up to 800 µA (400–0–400) µA |
Milliammeter
|
2,5; 4
|
from 1 mA (500–0–500) µA
up to 800 mA (400–0–400) mA |
Ammeter
|
2,5; 4
|
from 1 (0.5–0–0.5) A
up to 10 A (5-0-5) A and 75 (75-0-75) mV ** for use with an external shunt |
The overall dimensions, length of the scale and weight of the devices are given below:
Overall dimensions, mm
|
Scale length, no less, mm
|
Mass, no more, kg
|
60 х 60 х 48
|
45
|
0,2
|
Час установлення показів – 4 с.
Робочі умови застосування приладу:
– температура оточуючого повітря від мінус 50 ºС до плюс 60 ºС;
– відносна вологість повітря до 98 % за температури 35 ºС.
Прилади встановлюються в щит, розмітка щита (вид спереду) наведена на рисунку.

Shield marking for MA0202.